Hall CG, Abraham GN (1984) Size, shape, and hydration of a self-associating human IgG myeloma protein: axial asymmetry as a contributing factor in serum hyperviscosity. Goodall D (2012) Viscosity measurement apparatus and method. Garidel P, Kuhn AB, Schäfer LV et al (2017) High-concentration protein formulations: How high is high? Eur J Pharm Biopharm 119:353–360. Įinstein A (1906) Zur Theorie der Brownschen Bewegung. (01)89241-4Įinaga Y, Miyaki Y, Fujita H (1979) Intrinsic viscosity of polystyrene. ĭutta PK, Hammons K, Willibey B, Haney MA (1991) Analysis of protein denaturation by high-performance continuous differential viscometry. Ĭurvale R, Masuelli M, Padilla AP (2008) Intrinsic viscosity of bovine serum albumin conformers. Ĭilurzo F, Selmin F, Minghetti P et al (2011) Injectability evaluation: an open issue. Ĭhenal A, Guijarro JI, Raynal B et al (2009) RTX calcium binding motifs are intrinsically disordered in the absence of calcium: implication for protein secretion. Springer Japan, Tokyo, pp 169–193Ĭhatterjee A (1965) Intrinsic viscosity measurements of bovine serum albumin at different temperatures. In: Uchiyama S, Arisaka F, Stafford WF, Laue T (eds) Analytical ultracentrifugation: instrumentation, software, and applications. īrookes E, Rocco M (2016) Calculation of Hydrodynamic Parameters: US-SOMO. īai L, Zheng R, Li W et al (2013) A synthetic approach for water soluble hyperbranched poly(N, N-ethylidenebis(N-2-chloroacetyl acrylamide)) with high degree of branching via atom transfer radical polymerization/self-condensing vinyl polymerization. Īrora J, Hickey JM, Majumdar R et al (2015) Hydrogen exchange mass spectrometry reveals protein interfaces and distant dynamic coupling effects during the reversible self-association of an IgG1 monoclonal antibody. This simple and innovative approach should give a new boost to intrinsic viscosity measurements and should reignite the interest of biophysicists, immunologists, structural biologists and other researchers for this key physicochemical parameter.Īragon SR (2011) Recent advances in macromolecular hydrodynamic modeling. Altogether, our results show that the Viscosizer TD instrument is able to measure intrinsic viscosities in a straightforward manner. However, with respect to them, our measurements could be performed at relatively low concentrations, between 2 and 5 mg/ml, using only 7 µL per injection. The data obtained with our in-house protocol show a strong correlation with intrinsic viscosity values obtained using conventional techniques. The presence of P20 in the samples is critical to get reliable results. In this study, we then performed our assays on the Poly(ethylene oxide) polymer (PEO), used classically as a standard for viscometry measurements and on three model proteins: the bovine serum albumin (BSA), the bevacizumab monoclonal antibody, and the RTX Repeat Domain (RD) of the adenylate cyclase toxin of Bordetella pertussis (CyaA). To our knowledge, there are no studies to date showing that the Viscosizer TD instrument (Malvern-Panalytical) is able to measure the intrinsic viscosity of macromolecules. By design, these instruments behave like U-tube viscometers. These instruments monitor Taylor dispersion using an absorbance or fluorescence detector. Commercially available instruments measure intrinsic viscosity by recording the macromolecular mobility in a capillary. Intrinsic viscosity is a key hydrodynamic parameter to understand molecular structure and hydration, as well as intramolecular interactions.
0 Comments
Leave a Reply. |